Olly
Senior Member
Picogroup
***
Offline


Ollymoto

Posts: 113

Christchurch, New Zealand
Christchurch
New Zealand

Gender: male
Plused Starter Solonoid Signal
Aug 9th, 2014 at 2:27pm
 
This one came to us as MV Agusta agents from another garage after having been looking into it for almost a month after initially it was taken to the customers local garage to have a battery replaced.

When the tech fitted the battery and started the bike up he noticed that the starter solenoid had a rapid pulsing action when it was activated, rather than a steady on, hold, and off.

Initial they replaced the battery again, the starter solenoid before having the bike transported to us for further checks as they could only see that the ECM was the next faulty part.

The bike is an MV Agusta Brutale 989, the factory provide very little service info about the system other than the whole vehicle wiring diagram which i found online as it wasn't available on dealer portal.

From my understanding of the system, the start button the rider activates to start the bike switches a voltage to the ECM to let the ECM know to start the vehicle as long as all other conditions are met. The Computer then controlls the earthing of the starter solenoid winding's directly (with no other circuits included on this signal wire). The ECM has a timed system, as best i can tell, so given a no start situation the ECM only allows cranking for a given period of time.

I found the same symptoms when starting, the starter solenoid would pulse/rattle when activated. Although given this, the bike always started fine within a couple of revolutions and ran and drove well.

This is, by my and the other techs experience, an unusual way to activate a starter solenoid, from our experience with motorcycles at least. We both surmised that this rapid pulsing of the solenoid contacts would shorten the life of the solenoid considerably as a minimum.

We happened to have another Bike in the shop with the same ECM system which we were not aware of any faults with.

I started by scoping the triggered wire from the ECM at the solenoid on the faulty bike and found the waveform as posted. Batt volt with pulsing signal at regular 100ms intervals with ignition on, engine off, not cranking.

Under cranking the signal has the same signal but drops to ground between pulses. Hence giving the pulsing of the starter solenoid. Unusual we thought so carried out the same test on the other bike in shop with no reported faults. Exactly the same scenario.

Our conclusion is currently that this is a normal "feature" rather than a fault of the bike given that both bikes are identical and have no other reported faults. We suspect the pulsing is possibly how the ECM references time to establish when to stop cranking given a no start scenario.

I would appreciate any input or other thoughts if anyone has come across a similar system or issue before. The customer has taken the bike back and advised to report any future faults or symptoms if they present themselves.
Back to top
 

www.OllyMoto.co.nz
Motorcycle Servicing, Repairs & Diagnostics
WWW WWW 114447882049244  
IP Logged
 
JNelson
Super Nerd
Picogroup
*****
Offline


I'm an Autonerd

Posts: 684

Livermore, CA, California, USA
Livermore, CA
California
USA

Gender: male
Re: Plused Starter Solonoid Signal
Reply #1 - Aug 9th, 2014 at 5:55pm
 
Maybe it is a strategy to save the puny little battery from dumping all its amperage into the starter over 15 seconds.
Someone at the factory decided the engine cranked fast enough this way?
Back to top
 
 
IP Logged
 
Olly
Senior Member
Picogroup
***
Offline


Ollymoto

Posts: 113

Christchurch, New Zealand
Christchurch
New Zealand

Gender: male
Re: Plused Starter Solonoid Signal
Reply #2 - Aug 9th, 2014 at 10:46pm
 
Yea thats kind of what we thought, someine on the R&D teams unique idea. It seems to work fine and cant say i have replaced alot of solonoids yet but just interesting to find as without the other bike to test against you could quite easliy assume a fault there somewhere and get expensive real quickly.

How do other vehicles with ECM controlled starter activation calculate time allowd to crank before they shut off in a no start situation?
Back to top
 

www.OllyMoto.co.nz
Motorcycle Servicing, Repairs & Diagnostics
WWW WWW 114447882049244  
IP Logged
 
HarleyMike
Super Nerd
Picogroup
*****
Offline



Posts: 1,308

Dinwiddie County, Virginia, USA
Dinwiddie County
Virginia
USA

Gender: male
Re: Plused Starter Solonoid Signal
Reply #3 - Aug 11th, 2014 at 7:10am
 
On Nissan's with push button ignition the BCM waits for a signal from the ECM that the engine is in fact running, If the engine fails to start they will only crank for 5 seconds @ a time this is controlled by the BCM (body control module). All of this only happens if the security system is satisfied.

Olly wrote on Aug 9th, 2014 at 10:46pm:
How do other vehicles with ECM controlled starter activation calculate time allowd to crank before they shut off in a no start situation?

Back to top
 

~DatSoon Tech.~    Carter's Diagnostics on YouTube
 
IP Logged
 
autosparky
Super Nerd
Picogroup
*****
Offline


blind worker

Posts: 2,537

Porirua, New Zealand
Porirua
New Zealand

Gender: male
Re: Plused Starter Solonoid Signal
Reply #4 - Aug 11th, 2014 at 11:57pm
 
I agree about security system

Also it may stop someone accidently hitting the start button when the engine is already running

The pulse could be a self test to see if there's continuity with the starter solenoid.

Did you by any chance do a current draw test on that solenoid? where's that wiring diagram?
Back to top
 

can't see, can't hear, can't remember
 
IP Logged
 
Olly
Senior Member
Picogroup
***
Offline


Ollymoto

Posts: 113

Christchurch, New Zealand
Christchurch
New Zealand

Gender: male
Re: Plused Starter Solonoid Signal
Reply #5 - Aug 17th, 2014 at 11:48pm
 
autosparky wrote on Aug 11th, 2014 at 11:57pm:
I agree about security system

Also it may stop someone accidently hitting the start button when the engine is already running

The pulse could be a self test to see if there's continuity with the starter solenoid.

Did you by any chance do a current draw test on that solenoid? where's that wiring diagram?


Sorry i didn't do a current draw test on the solonoid. I Have attached a PDF of the wiring diagram and key as supplied by manufacturer. Item 16 is the solonoid and the wire is teh one off to the left(wire colours are pooly marked, its an orange wire)
Let me know your thoughts.

There is no "security" system i know of on this particular model, no ommobiliser and no transponder key. Should be simple by all accounts. Undecided
Back to top
 

www.OllyMoto.co.nz
Motorcycle Servicing, Repairs & Diagnostics
WWW WWW 114447882049244  
IP Logged
 
autosparky
Super Nerd
Picogroup
*****
Offline


blind worker

Posts: 2,537

Porirua, New Zealand
Porirua
New Zealand

Gender: male
Re: Plused Starter Solonoid Signal
Reply #6 - Aug 18th, 2014 at 1:21am
 
what a useless diagram, totally Italian!!

see item 45?? anti theft connector

From what I can make out, there's 5 wires

-battery cable
-cable to starter
-ground signal from 1 CPU
-another battery supply to the 2 bottom connectors*not sure what's it for
-43 service control unit,  37 light switch** somehow it comes from the ignition switch but it's not very clear

sorry that's all I can make out
Back to top
 

can't see, can't hear, can't remember
 
IP Logged
 
M-TEKK1
Freshman Member
*
Offline


I'm an Autonerd

Posts: 3

Zion Illinois, Illinois, USA
Zion Illinois
Illinois
USA

Re: Plused Starter Solonoid Signal
Reply #7 - Mar 11th, 2016 at 5:43pm
 
You state that the ecm controls the solenoid directly.  By pulsing the starter solenoid it can control current flow on that circuit.  Im only assuming that the above logic is applied here
Back to top
 
 
IP Logged